網站建置中,敬請期待
Compact Design
Light Weight
Sealed Unit
AC or Battery Operation
Front Panel Indicators Provide Status of Critical Functions
Array Support
RFT Support
NFT Support
RPC Probe Support
OMNI-Helium with Bobbin Adapter
Two LI-ION Rechargeable Batteries
Battery Charger
Power Cord
Ground Strap
Carry Strap
Certificate of Calibration
Shipping Case
Differential/Absolute Bobbin
High Voltage Remote Field (no preamp necessary)
RFT Support
CoreStar Array: Full Length, Wand, Surface Scanning
CoreStar NFT probe support
Zetec Array: X-Probe, CXB
Air Conditioning: DC2/AC3
Calibration (provides functionality to calibrate system in-house with additional equipment)
Utilizes Digital Demodulation
Four Frequency Simultaneous Injection Improves Response for Low Frequency Applications Including RFT
Supports up to 16 Time Slots and up to Four Frequencies per Time Slot
Dynamic Gain Minimizes Saturated and Clipped Data
Impedance Matching Improves Dynamic Range of Mismatched Probe Coils
Internal Reference Option Generates Absolute Signals without a Reference Probe
Interchangable Probe Modules Accomodate Bobbin, Driver/Pickup, Flux Leakage, RPC, and Array Probes
Sixteen Isolated I/O Lines and Three Isolated Quadrature Encoder Inputs for Remote Control Functions and Material Handling
Front Panel Indicators Provide Status for Processor Function, DC Voltages, Ethernet Connectivity, Temperature, and Fault Conditions
Rubber Bezels Protect Case During Field Use
Lifetime Warranty Shipping Case Included
Power 100-250 VAC 50/60 Hz
Size 17.88W x 14.25D x 10.0H in
45.42W x 36.2D x 25.4H cm
Weight 22lbs 10kg
Environmental 32 to 113°F (0 to 45°C) Operating Range, -4 to 158° (-20 to 70°C) Storage
Interface Four Port 10/100 Ethernet Switch
Frequency Range 20 Hz to 5 MHz
ET: 100Hz to 5 MHz
RFT: 20Hz to 100 KHz
Drive Voltage ET: 0 to 20 Vpp
RFT: 0 to 60 Vpp (300ma Protected)
System Gain -22 to 20 db Adjustable
Preamp Gain 0 to 700 Adjustable
Frequency Generators 4 Multiplexed or Simultaneous
Channel Capacity Simultaneous Mode 32
Multiplexed Mode 128
Context Mode 512
Impedance Matching Improves Range of Mismatched Coils
Hardware Null Minimizes DC Offset in Multi-Coil Applications
Sampling Mode Time Based 100 to 10,000 samples/sec
Distance Based: English or Metric Selectable
Status and Diagnostic Voltage and Temperature Monitoring (Software)
Input/Outputs Sixteen Isolated I/O Lines (User Powered)
Three Isolated Quadrature Encoder Inputs (User Powered)
AM-205 Module:
CoreStar Array Probe
Zetec X-Probe
Differential/Absolute Bobbin Probes
Drive/Receive Probes
Conventional DC RPC Motor Units and 3-Phase Brushless RPC Motor Units
The module is supplied with a front panel 55-pin signal connector and a 4-pin connector for an external RPC power supply.
Probe adapters are required for all probes except the CoreStar Array:
A 55 to 4-pin adapter for bobbin probes is included with the module purchase.
Probe adapters for the remaining supported probe types are available at an additional cost.
The adapter for the RPC probes includes the external power supply.